| Main | Detail |
|---|---|
| Category | Inserts |
| Series | Han-Com® |
| Identification | Han® K 9/9/18 |
| Termination method | Crimp termination |
| Gender | Female |
| Size | 16 B |
| Number of contacts | 36 |
| Number of signal contacts | 18 |
| Number of power contacts | 18 |
| PE contact | Yes |
| Details | Please order crimp contacts separately.9x Han® C9x Han E®18x Han D®To ensure a preleading PE-contact under all conditionsit is necessary to use guide pins/bushes (09 33 000 9908 / 09 33 000 9909). |
| Conductor cross-section | 1.5 ... 6 mm² Power0.14 ... 4 mm² Power0.14 ... 2.5 mm² Signal |
| Rated current (signal) | 10 A |
| Rated voltage (signal) | 250 V |
| Rated impulse voltage (signal) | 4 kV |
| Pollution degree (signal) | 3 |
| Rated current (power) | 40 A16 A |
| Rated voltage (power) | 830 V |
| Rated impulse voltage (power) | 8 kV |
| Pollution degree (power) | 3 |
| Insulation resistance | >1010 Ω |
| Limiting temperature | -40 ... +125 °C |
| Mating cycles | ≥ 500 |
| Material (insert) | Polycarbonate (PC) |
| Colour (insert) | RAL 7032 (pebble grey) |
| Material flammability class acc. to UL 94 | V-0 |
| RoHS | compliant |
| ELV status | compliant |
| China RoHS | e |
| REACH Annex XVII substances | Not contained |
| REACH ANNEX XIV substances | Not contained |
| REACH SVHC substances | Not contained |
| California Proposition 65 substances | YesLeadNickel |
| Fire protection on railway vehicles | EN 45545-2 (2020-08) |
| Requirement set with Hazard Levels | R22 (HL 1-3)R23 (HL 1-3) |
| Specifications | IEC 60664-1IEC 61984 |
| Approvals | DNV GL |
| Packaging size | 1 |
| Net weight | 68 g |
| Country of origin | Romania |
| European customs tariff number | 85366990 |
| GTIN | 5713140186460 |
| ETIM | EC000438 |
| eCl@ss | 27440205 Contact insert for industrial connectors |