SHAIRAD SANAT
SHAIRAD SANAT
SHAIRAD SANAT
SEPAMM87

Images

  • Product Nav 0
  • SEPAMM87

Documents

SEPAMM87 pdf
105.21 KB

SEPAMM87

SKU : SEPAMM87

Schneider Electric Sepam series 80 for Motor M87 SEPAMM87

  Shairad Sanat is the exclusive and official representative of more than 10 European and Asian brands. This company is able to meet the needs of customers in the best possible way and in the shortest possible time, using the scientific and practical experience, modern management systems and employing expert and experienced staff.
Main Detail
relay application

Motor

range of product

Sepam series 80 Sepam series 80 NPP

device short name

M87

control and monitoring type

Circuit breaker/contactor control ANSI code: 94/69 (option) Latching/acknowledgement ANSI code: 86 Logic discrimination ANSI code: 68 (option) Switching of groups of settings Annunciation ANSI code: 30 Logipam programming (ladder language) (option) Logic equation editor 200 operators Load shedding/automatic restart

metering type

Positive sequence voltage Vd/rotation direction Frequency Calculated active and reactive energy (+/- W.h, +/- VAR.h) Active and reactive energy by pulse counting (+/- W.h, +/- VAR.h) (option) Phase current I1, I2, I3 RMS Demand current I1, I2, I3 Peak demand current IM1, IM2, IM3 Measured residual current I

network and machine diagnosis type

Unbalance ratio/negative sequence current Ii Disturbance recording Thermal capacity used Remaining operating time before overload tripping Waiting time after overload tripping Running hours counter/operating time Starting current and time Start inhibit time, number of starts before inhibition Tripping context Phase fault and earth fault trip counters Harmonic distortion (THD), current and voltage Ithd, Uthd Apparent positive sequence impedance Zd Apparent phase-to-phase impedances Z21, Z32, Z13 Differential current Idiff1, idiff2, Idiff3 Through current It1, It2, It3 Current phase displacement θ Phase displacement Datalog (DLG) Motor start report (MSR) Motor start trend (MST)

switchgear diagnosis type

Cumulative breaking current CT/VT supervision ANSI code: 60FL Trip circuit supervision ANSI code: 74 (option) Auxiliary power supply monitoring Nb of operations, operating time, charging time, nb of racking out operations (option)

Wave

محصولات مرتبط

    COMPARE ITEMS

    Call US

    Contact US :

    Address : No.21, 7th Alley, Niloofar St, Khorramshahr Ave, Tehran-Iran
    Phone Number : 88764999 21 98 +
    Mobile Number : 2202380 920 98 +
    Email Address : [email protected]


    Contact