SEPAMM88

Images

  • Product Nav 0
  • SEPAMM88

Documents

SEPAMM88 pdf
105.42 KB

SEPAMM88

SKU : SEPAMM88

Schneider Electric Sepam series 80 for Motor M88 SEPAMM88

  Shairad Sanat is the exclusive and official representative of more than 10 European and Asian brands. This company is able to meet the needs of customers in the best possible way and in the shortest possible time, using the scientific and practical experience, modern management systems and employing expert and experienced staff.
Main Detail
relay application

Generator

range of product

Sepam series 80 NPP Sepam series 80

device short name

G88

control and monitoring type

Circuit breaker/contactor control ANSI code: 94/69 (option) Latching/acknowledgement ANSI code: 86 Logic discrimination ANSI code: 68 (option) Switching of groups of settings Annunciation ANSI code: 30 Automatic transfer (AT) (option) Logipam programming (ladder language) (option) Logic equation editor 200 operators

metering type

Positive sequence voltage Vd/rotation direction Frequency Calculated active and reactive energy (+/- W.h, +/- VAR.h) Active and reactive energy by pulse counting (+/- W.h, +/- VAR.h) (option) Phase current I1, I2, I3 RMS Demand current I1, I2, I3 Peak demand current IM1, IM2, IM3 Measured residual current I'0 Voltage U21, U32, U13, V1, V2, V3 Residual voltage V0 Negative sequence voltage Vi Active power P, P1, P2, P3 Reactive power Q, Q1, Q2, Q3 Apparent power S, S1, S2, S3 Peak demand power PM, QM Power factor Temperature (16 RTDs) (option) Phase current I'1, I'2, I'3 RMS Rotation speed (option) Neutral point voltage Vnt Measured residual current I0, calculated I'0∑ Calculated residual current I'0∑

network and machine diagnosis type

Unbalance ratio/negative sequence current Ii Disturbance recording Thermal capacity used Remaining operating time before overload tripping Waiting time after overload tripping Running hours counter/operating time Tripping context Phase fault and earth fault trip counters Harmonic distortion (THD), current and voltage Ithd, Uthd Difference in amplitude, frequency and phase of voltages with synchro-check option Apparent positive sequence impedance Zd Apparent phase-to-phase impedances Z21, Z32, Z13 Differential current Idiff1, idiff2, Idiff3 Through current It1, It2, It3 Third harmonic voltage, neutral point residual Current phase displacement θ Phase displacement Datalog (DLG)

switchgear diagnosis type

Cumulative breaking current CT/VT supervision ANSI code: 60FL Trip circuit supervision ANSI code: 74 (option) Auxiliary power supply monitoring Nb of operations, operating time, charging time, nb of racking out operations (option)