SEPAMC86

Images

  • Product Nav 0
  • SEPAMC86

Documents

SEPAMC86 pdf
96.79 KB

SEPAMC86

SKU : SEPAMC86

Schneider Electric Sepam series 80 for Capacitor C86 SEPAMC86

  Shairad Sanat is the exclusive and official representative of more than 10 European and Asian brands. This company is able to meet the needs of customers in the best possible way and in the shortest possible time, using the scientific and practical experience, modern management systems and employing expert and experienced staff.
Main Detail
relay application

Capacitor

range of product

Sepam series 80 Sepam series 80 NPP

device short name

C86

control and monitoring type

Circuit breaker/contactor control ANSI code: 94/69 (option) Latching/acknowledgement ANSI code: 86 Logic discrimination ANSI code: 68 (option) Switching of groups of settings Annunciation ANSI code: 30 Logipam programming (ladder language) (option) Logic equation editor 200 operators Capacitor step control (option)

metering type

Positive sequence voltage Vd/rotation direction Frequency Calculated active and reactive energy (+/- W.h, +/- VAR.h) Active and reactive energy by pulse counting (+/- W.h, +/- VAR.h) (option) Phase current I1, I2, I3 RMS Demand current I1, I2, I3 Peak demand current IM1, IM2, IM3 Voltage U21, U32, U13, V1, V2, V3 Residual voltage V0 Negative sequence voltage Vi Active power P, P1, P2, P3 Reactive power Q, Q1, Q2, Q3 Apparent power S, S1, S2, S3 Peak demand power PM, QM Power factor Temperature (16 RTDs) (option) Measured residual current I0, calculated I

network and machine diagnosis type

Unbalance ratio/negative sequence current Ii Disturbance recording Thermal capacity used Remaining operating time before overload tripping Waiting time after overload tripping Running hours counter/operating time Tripping context Phase fault and earth fault trip counters Harmonic distortion (THD), current and voltage Ithd, Uthd Apparent positive sequence impedance Zd Apparent phase-to-phase impedances Z21, Z32, Z13 Capacitor unbalance current and capacitance Phase displacement Datalog (DLG)

switchgear diagnosis type

Cumulative breaking current CT/VT supervision ANSI code: 60FL Trip circuit supervision ANSI code: 74 (option) Auxiliary power supply monitoring Nb of operations, operating time, charging time, nb of racking out operations (option)