SHAIRAD SANAT
SHAIRAD SANAT
SHAIRAD SANAT
SEPAMG82

Images

  • Product Nav 0
  • SEPAMG82

Documents

SEPAMG82 pdf
106.04 KB

SEPAMG82

SKU : SEPAMG82

Schneider Electric Sepam series 80 for Generator G82 SEPAMG82

  Shairad Sanat is the exclusive and official representative of more than 10 European and Asian brands. This company is able to meet the needs of customers in the best possible way and in the shortest possible time, using the scientific and practical experience, modern management systems and employing expert and experienced staff.
Main Detail
relay application

Generator

range of product

Sepam series 80 Sepam series 80 NPP

device short name

G82

control and monitoring type

Positive sequence voltage Vd/rotation direction Frequency Calculated active and reactive energy (+/- W.h, +/- VAR.h) Active and reactive energy by pulse counting (+/- W.h, +/- VAR.h) (option) Phase current I1, I2, I3 RMS Demand current I1, I2, I3 Peak demand current IM1, IM2, IM3 Measured residual current I'0 Voltage U21, U32, U13, V1, V2, V3 Residual voltage V0 Negative sequence voltage Vi Active power P, P1, P2, P3 Reactive power Q, Q1, Q2, Q3 Apparent power S, S1, S2, S3 Peak demand power PM, QM Power factor Temperature (16 RTDs) (option) Rotation speed (option) Neutral point voltage Vnt Measured residual current I0, calculated I'0∑

metering type

Positive sequence voltage Vd/rotation direction Frequency Calculated active and reactive energy (+/- W.h, +/- VAR.h) Active and reactive energy by pulse counting (+/- W.h, +/- VAR.h) (option) Phase current I1, I2, I3 RMS Demand current I1, I2, I3 Peak demand current IM1, IM2, IM3 Measured residual current I'0 Voltage U21, U32, U13, V1, V2, V3 Residual voltage V0 Negative sequence voltage Vi Active power P, P1, P2, P3 Reactive power Q, Q1, Q2, Q3 Apparent power S, S1, S2, S3 Peak demand power PM, QM Power factor Temperature (16 RTDs) (option) Rotation speed (option) Neutral point voltage Vnt Measured residual current I0, calculated I'0∑

network and machine diagnosis type

Unbalance ratio/negative sequence current Ii Disturbance recording Thermal capacity used Remaining operating time before overload tripping Waiting time after overload tripping Running hours counter/operating time Tripping context Phase fault and earth fault trip counters Harmonic distortion (THD), current and voltage Ithd, Uthd Difference in amplitude, frequency and phase of voltages with synchro-check option Apparent positive sequence impedance Zd Apparent phase-to-phase impedances Z21, Z32, Z13 Third harmonic voltage, neutral point residual Phase displacement Datalog (DLG)

switchgear diagnosis type

Cumulative breaking current CT/VT supervision ANSI code: 60FL Trip circuit supervision ANSI code: 74 (option) Auxiliary power supply monitoring Nb of operations, operating time, charging time, nb of racking out operations (option)

Wave

محصولات مرتبط

    COMPARE ITEMS

    Call US

    Contact US :

    Address : No.21, 7th Alley, Niloofar St, Khorramshahr Ave, Tehran-Iran
    Phone Number : 88764999 21 98 +
    Mobile Number : 2202380 920 98 +
    Email Address : [email protected]


    Contact