SHAIRAD SANAT
SHAIRAD SANAT
SHAIRAD SANAT
LC1D38FD

Images

  • Product Nav 0
  • LC1D38FD

Documents

LC1D38FD pdf
123.13 KB

LC1D38FD

SKU : LC1D38FD

Main Detail
Range

TeSys

Product Name

TeSys D

Type of product or equipment
Name of the device
contactor application

Resistive load
Motor control

Job Category
Description of the poles
power pole contact composition
(Ue) rated operational voltage

Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC

(Ie) rated operational current

50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 38 A (at <60 °C) at <= 440 V AC AC-3 for power circuit

motor power kW

18.5 KW at 500 V AC 50/60 Hz (AC-3)
18.5 KW at 660...690 V AC 50/60 Hz (AC-3)
7.5 KW at 400 V AC 50/60 Hz (AC-4)
18.5 KW at 380...400 V AC 50/60 Hz (AC-3)
9 KW at 220...230 V AC 50/60 Hz (AC-3)
18.5 KW at 415...440 V AC 50/60 Hz (AC-3)

motor power HP (UL / CSA)

10 Hp at 230/240 V AC 50/60 Hz for 3 phases motors
10 Hp at 200/208 V AC 50/60 Hz for 3 phases motors
5 Hp at 240 V AC 50/60 Hz for 1 phase motors
20 Hp at 480 V AC 50/60 Hz for 3 phases motors
25 Hp at 600 V AC 50/60 Hz for 3 phases motors

control circuit type

DC standard

control circuit voltage

110 V DC

Auxiliary contacts
(Uimp) rated impulse withstand voltage

6 KV conforming to IEC 60947

Overvoltage category

III

(Ith) conventional thermal current
nominal switching capacity Irms
rated breaking capacity

550 A at 440 V for power circuit conforming to IEC 60947

(Icw) rated short-time withstand current

60 A 40 °C - 10 min for power circuit
430 A 40 °C - 1 s for power circuit
150 A 40 °C - 1 min for power circuit
310 A 40 °C - 10 s for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit

fuse rating to be associated
average impedance

2 MOhm - Ith 50 A 50 Hz for power circuit

(Ui) rated insulation voltage

Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Power circuit: 690 V conforming to IEC 60947-4-1

electrical life
power dissipated per pole
Front cover
Mounting bracket
Standards

CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508

Product certifications

CCC
LROS (Lloyds register of shipping)
DNV
UL
GL
BV
GOST
CSA
RINA

connection mode
tightening torque

Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2

Operating time

16...24 ms opening
53.55...72.45 ms closing

security reliability level
Mechanical endurance
maximum control speed
Wave