Schneider Electric TeSys D contactor 3P(3NO) AC3 <= 440 V 95A 45 KW coil 24VDC LC1D95BD

  Shairad Sanat is the exclusive and official representative of more than 10 European and Asian brands. This company is able to meet the needs of customers in the best possible way and in the shortest possible time, using the scientific and practical experience, modern management systems and employing expert and experienced staff.
Main Detail
Range

TeSys

Product Name

TeSys D

Type of product or equipment
Name of the device
contactor application

Resistive load
Motor control

Job Category
Description of the poles
power pole contact composition

3 NO

(Ue) rated operational voltage

Power circuit: 1000 V AC 25...400 Hz

(Ie) rated operational current

95 A (at <60 °C) at <= 440 V AC-3 for power circuit 125 A (at <60 °C) at <= 690 V AC-1 for power circuit

motor power kW

25 kW at 220...230 V AC 50 Hz (AC-3)
45 kW at 380...400 V AC 50 Hz (AC-3)
45 kW at 415...440 V AC 50 Hz (AC-3)
55 kW at 500 V AC 50 Hz (AC-3)
45 kW at 660...690 V AC 50 Hz (AC-3)
45 kW at 1000 V AC 50 Hz (AC-3)

motor power HP (UL / CSA)

7.5 hp at 115 V AC 60 Hz for 1 phase motors
15 hp at 230/240 V AC 60 Hz for 1 phase motors
25 hp at 200/208 V AC 60 Hz for 3 phases motors
30 hp at 230/240 V AC 60 Hz for 3 phases motors
60 hp at 460/480 V AC 60 Hz for 3 phases motors
60 hp at 575/600 V AC 60 Hz for 3 phases motors

control circuit type

DC standard

control circuit voltage

24 V DC

Auxiliary contacts
(Uimp) rated impulse withstand voltage

8 kV conforming to IEC 60947

Overvoltage category

III

(Ith) conventional thermal current
nominal switching capacity Irms
rated breaking capacity

1100 A at 440 V for power circuit conforming to IEC 60947

(Icw) rated short-time withstand current

1100 A 40 °C - 1 s for power circuit
800 A 40 °C - 10 s for power circuit
400 A 40 °C - 1 min for power circuit
135 A 40 °C - 10 min for power circuit
140 A - 100 ms for signalling circuit
120 A - 500 ms for signalling circuit
100 A - 1 s for signalling circuit

fuse rating to be associated
average impedance

0.8 mOhm - Ith 125 A 50 Hz for power circuit

(Ui) rated insulation voltage

Power circuit: 1000 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-1

electrical life
power dissipated per pole
Front cover
Mounting bracket
Standards

EN/IEC 60947-1
EN/IEC 60947-4-1
EN/IEC 60947-5-1
GB/T 14048.4

Product certifications

IECEE CB Scheme
CCC
EAC
LROS (Lloyds register of shipping)
RINA
BV
DNV-GL

connection mode
tightening torque

Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2
Power circuit: 9 N.m - on connector - with screwdriver flat Ø 6 to Ø 8 mm
Power circuit: 9 N.m - on connector hexagonal screw head 4 mm

Operating time

95...130 ms closing
20...35 ms opening

security reliability level
Mechanical endurance
maximum control speed
Wave