LC1D18ED

Images

  • Product Nav 0
  • LC1D18ED

Documents

LC1D18ED pdf
82.36 KB

LC1D18ED

SKU : LC1D18ED

Main Detail
Range

TeSys

Product Name

TeSys D

Type of product or equipment
Name of the device
contactor application

Motor control
Resistive load

Job Category
Description of the poles
power pole contact composition
[Ue

Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC

[Ie

18 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 32 A (at <60 °C) at <= 440 V AC AC-1 for power circuit

motor power kW

4 KW at 220...230 V AC 50/60 Hz (AC-3)
7.5 KW at 380...400 V AC 50/60 Hz (AC-3)
9 KW at 415...440 V AC 50/60 Hz (AC-3)
10 KW at 500 V AC 50/60 Hz (AC-3)
10 KW at 660...690 V AC 50/60 Hz (AC-3)
4 KW at 400 V AC 50/60 Hz (AC-4)

motor power HP (UL / CSA)
control circuit type

DC standard

control circuit voltage
Auxiliary contacts
[Uimp

6 KV conforming to IEC 60947

Overvoltage category

III

[Ith
nominal switching capacity Irms
rated breaking capacity

300 A at 440 V for power circuit conforming to IEC 60947

[Icw

145 A 40 °C - 10 s for power circuit
240 A 40 °C - 1 s for power circuit
40 A 40 °C - 10 min for power circuit
84 A 40 °C - 1 min for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit

fuse rating to be associated
average impedance

2.5 MOhm - Ith 32 A 50 Hz for power circuit

[Ui

Power circuit: 690 V conforming to IEC 60947-4-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified

electrical life
power dissipated per pole
Front cover
Mounting bracket
Standards

CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508

Product certifications

UL
DNV
RINA
CCC
GL
GOST
CSA
LROS (Lloyds register of shipping)
BV

connection mode
tightening torque

Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2

Operating time

53.55...72.45 ms closing
16...24 ms opening

security reliability level

B10d = 1369863 cycles contactor with nominal load conformingto
EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conformingto
EN/ISO 13849-1

Mechanical endurance
maximum control speed
Wave