SEPAMG60

Images

  • Product Nav 0
  • SEPAMG60

Documents

SEPAMG60 pdf
104.70 KB

SEPAMG60

SKU : SEPAMG60

Schneider Electric Sepam series 60 for Generator G60 SEPAMG60

  Shairad Sanat is the exclusive and official representative of more than 10 European and Asian brands. This company is able to meet the needs of customers in the best possible way and in the shortest possible time, using the scientific and practical experience, modern management systems and employing expert and experienced staff.
Main Detail
relay application

Generator

range of product

Sepam series 60

device short name

G60

control and monitoring type

Circuit breaker/contactor control ANSI code: 94/69 (option) Latching/acknowledgement ANSI code: 86 Logic discrimination ANSI code: 68 (option) Switching of groups of settings Annunciation ANSI code: 30 Automatic transfer (AT) (option) Logic equation editor 200 operators

metering type

Positive sequence voltage Vd/rotation direction Frequency Calculated active and reactive energy (+/- W.h, +/- VAR.h) Active and reactive energy by pulse counting (+/- W.h, +/- VAR.h) (option) Phase current I1, I2, I3 RMS Demand current I1, I2, I3 Peak demand current IM1, IM2, IM3 Voltage U21, U32, U13, V1, V2, V3 Residual voltage V0 Negative sequence voltage Vi Active power P, P1, P2, P3 Reactive power Q, Q1, Q2, Q3 Apparent power S, S1, S2, S3 Peak demand power PM, QM Power factor Temperature (16 RTDs) (option) Rotation speed (option) Measured residual current I0, calculated I'0∑

network and machine diagnosis type

Unbalance ratio/negative sequence current Ii Disturbance recording Thermal capacity used Remaining operating time before overload tripping Waiting time after overload tripping Running hours counter/operating time Tripping context Phase fault and earth fault trip counters Harmonic distortion (THD), current and voltage Ithd, Uthd Difference in amplitude, frequency and phase of voltages with synchro-check option Apparent positive sequence impedance Zd Apparent phase-to-phase impedances Z21, Z32, Z13 Third harmonic voltage, neutral point residual Cable arcing fault detection Phase displacement Datalog (DLG)

switchgear diagnosis type

Cumulative breaking current CT/VT supervision ANSI code: 60FL Trip circuit supervision ANSI code: 74 (option) Nb of operations, operating time, charging time, nb of racking out operations (option)